So are there counterparts to the
NCP transient in the HBA/RSM
data?
G. Pietka, R. Fender, T. Hassall, A. Stewart
Amsterdam, January 8, 2014
Slide 2
Slide 2 text
RSM low DM directions
●
Concentrate search for FRBs to RSM pointings
with a low DM
●
This means 7 out of 48 pointings ~ 220 deg2
●
6 Zenith scans
●
2 x 10 min snapshots
per scan.
An ideal low DM RSM strip
Slide 3
Slide 3 text
RSM low DM directions
●
RSM short-timescale imaging
●
Using one band (149 MHz) out of the 4 used in
the RSM.
●
Eg. 2 Mins
6 Zenith scans
x 2 snapshots
x 5 (2min) epochs
= 60 x 2min epochs
An ideal low DM RSM strip
Slide 4
Slide 4 text
Estimating FRB Rates in RSM
ν
NCP
=60 MHz
t
NCP
=660s
ν
RSM
=149 MHz
t∼ν−4 ⇒ t
RSM
=17s
25 Jy FRB candidate lasting 11 minutes found in NCP data at 60
MHz:
At the frequency of RSM data, the pulse width
will be scaled according to the scatter broadening:
Assume NCP Transient is Real
(and duration was scattering-dominated):
Slide 5
Slide 5 text
FRB Rates in 10s RSM Images
FoV
NCP
=175deg2
Nr of epochs
NCP
=1897
FoV
RSM
=219deg2
Nr of epochs
RSM
=720
Flux limit = 4 Jy Flux limit =1Jy
R
RSM (1Jy)
=
219deg2×720 epochs
175deg2×1897 epochs
×(
1Jy
4 Jy
)
−3/2
=3.8
R∝F−3/2
α=0
First for spectral index , 25 Jy NCP source will be 25 Jy also in
the RSM data.
So we would expect 3.8 NCP-Like transients in 10s RSM
Low DM search
Slide 6
Slide 6 text
FRB Rates in 10s RSM Images
R
RSM (1Jy)
=3.8×[(
ν
NCP
ν
RSM
)
α
]
−3/2
=3.8×f R∝F−3/2
Take the range of spectral index values -3 ≤ α ≤ 0
Expected number of
NCP-Like transients in
10s RSM Low DM
search for a range of
spectral index values
α f RSM Rate
0 1 3.8
-1 0.25 0.97
-2 0.065 0.248
-3 0.017 0.063
Slide 7
Slide 7 text
FRB Rates in 10s RSM Images
α=−3
For spectral index
F
NCP
=25 Jy F
RSM
=1.63 Jy
Source at the RSM detection limit of 1 Jy in the NCP band will be
15 Jy bright.
R
RSM (1Jy)
=
219deg2×720 epochs
175deg2×1897 epochs
×R
NCP(15Jy)
N
NCP(15Jy)
=N
NCP(4Jy)
×(
15
4
)
−3/2
N
NCP(15Jy)
=0.14
Slide 8
Slide 8 text
FRB Rates in 10s RSM Images
R
RSM (1Jy)
=
219deg2×720 epochs
175deg2×1897 epochs
×0.14
R
RSM (1Jy)
=0.07 For the spectral index α=−3
Slide 9
Slide 9 text
FRB Rates in 2min RSM Images
R
RSM (1Jy)
=
219deg2×60 epochs
175deg2×1897 epochs
×(
1Jy
4 Jy
)
−3/2
=0.3
α=0
For spectral index
However, there are other possible transient candidates in 2 minute
images...
Slide 10
Slide 10 text
2 Minute RSM Snapshots TraP
Transient Candidate #929
July 13, 17.14 July 13, 17.16
Example of type of events reported by TraP that need to be tested
and understood
Slide 11
Slide 11 text
2 Minute RSM Snapshots TraP
Transient Candidate #929
July 13, 17.14 July 13, 17.16
Slide 12
Slide 12 text
#929 Detection in 10s Images
Slide 13
Slide 13 text
#929 Detection in 10s Images
Slide 14
Slide 14 text
Deep 10 Minute Image of the Field
●
No source visible in
deeper 10 minute
image.
●
But artifacts in short
time scale imaging not
well understood.
Slide 15
Slide 15 text
Conclusions
●
~20s time scale NCP like events expected in the RSM field
●
Rate of NCP like events in a spectral index range -3 and 0
expected in the RSM low DM 10 s data: 0.07 - 4
●
Possible transient candidate selected by TraP in the RSM
data
●
More tests need to be done ...
Slide 16
Slide 16 text
If No Transients in RSM Data
Rate=−
−ln 0.05
FoV ×Nr of epochs
Rate
10s
=−
−ln 0.05
FoV ×Nr of epochs
=−
−ln 0.05
219deg2×720
=1.9×10−5 deg−2
Rate
2mins
=−
−ln 0.05
FoV ×Nr of epochs
=−
−ln 0.05
219deg2×60
=2×10−4 deg−2