Slide 1

Slide 1 text

Magnetic actuator for the control and mixing of magnetic bead- based reactions on-chip Miguel Berenguel Alonso Jornades Doctorals 2014 G B S Grup de Sensors i Biosensors

Slide 2

Slide 2 text

No content

Slide 3

Slide 3 text

Poster FP 1.4 [email protected]

Slide 4

Slide 4 text

No content

Slide 5

Slide 5 text

No content

Slide 6

Slide 6 text

Magnetic Beads

Slide 7

Slide 7 text

Magnetic Beads Control

Slide 8

Slide 8 text

Magnetic Beads Functionalization Control

Slide 9

Slide 9 text

X Magnetic Beads Functionalization Control Chemical Group DNA Antibody Other

Slide 10

Slide 10 text

Magnetic Beads Functionalization Control X

Slide 11

Slide 11 text

Magnetic Beads Functionalization Control Commercial X

Slide 12

Slide 12 text

Magnetic Beads Functionalization Control Commercial X Great Potential in Analysis

Slide 13

Slide 13 text

No content

Slide 14

Slide 14 text

Lab on a Chip

Slide 15

Slide 15 text

Lab on a Chip

Slide 16

Slide 16 text

Lab on a Chip

Slide 17

Slide 17 text

Lab on a Chip

Slide 18

Slide 18 text

Reaction Chamber Lab on a Chip

Slide 19

Slide 19 text

Reaction Chamber Lab on a Chip

Slide 20

Slide 20 text

Detection Chamber Reaction Chamber Lab on a Chip

Slide 21

Slide 21 text

Detection Chamber Reaction Chamber Lab on a Chip

Slide 22

Slide 22 text

Fabrication Process Lab on a Chip

Slide 23

Slide 23 text

Fabrication Process A Lab on a Chip

Slide 24

Slide 24 text

Fabrication Process A B Lab on a Chip

Slide 25

Slide 25 text

Fabrication Process A B C Lab on a Chip

Slide 26

Slide 26 text

Fabrication Process A B C D Lab on a Chip

Slide 27

Slide 27 text

No content

Slide 28

Slide 28 text

Advantages Lab on a Chip Magnetic Beads

Slide 29

Slide 29 text

Limitations Lab on a Chip Magnetic Beads

Slide 30

Slide 30 text

No content

Slide 31

Slide 31 text

How do I control the MBs within the Microfluidic Chip?

Slide 32

Slide 32 text

No content

Slide 33

Slide 33 text

Magnetic Actuator Magnet Assembly Rotation MB Movement Magnet Pairs

Slide 34

Slide 34 text

Magnetic Actuator Magnetic Rotation Axis Magnets Beads

Slide 35

Slide 35 text

Magnetic Actuator 0º

Slide 36

Slide 36 text

Magnetic Actuator 90º 0º

Slide 37

Slide 37 text

Magnetic Actuator 90º 180º 0º

Slide 38

Slide 38 text

Magnetic Actuator 90º 180º 0º 270º

Slide 39

Slide 39 text

Magnetic Actuator 270º 180º 90º 0º

Slide 40

Slide 40 text

Magnetic Actuator Magnetic Rotation Axis Magnets Beads

Slide 41

Slide 41 text

Magnetic Actuator Magnetic Rotation Axis Magnets Beads What kind of magnet(s)?

Slide 42

Slide 42 text

Magnetic Actuator Dr. X. Granados Dr. J. Faraudo

Slide 43

Slide 43 text

Magnetic Actuator Simulation

Slide 44

Slide 44 text

Magnetic Actuator B Magnet Couple

Slide 45

Slide 45 text

No content

Slide 46

Slide 46 text

No content

Slide 47

Slide 47 text

The actuator enhances the microfluidic immunoassay by actively mixing

Slide 48

Slide 48 text

No content

Slide 49

Slide 49 text

Immunoassay E. Coli O157:H7

Slide 50

Slide 50 text

Immunoassay E. Coli O157:H7 Enterohemorragic strain

Slide 51

Slide 51 text

Immunoassay E. Coli O157:H7 Enterohemorragic strain Present in food

Slide 52

Slide 52 text

Immunoassay E. Coli O157:H7 Enterohemorragic strain Present in food

Slide 53

Slide 53 text

Immunoassay E. Coli O157:H7 Enterohemorragic strain Present in food Commercial MBs

Slide 54

Slide 54 text

Immunoassay

Slide 55

Slide 55 text

Immunoassay Off-Chip

Slide 56

Slide 56 text

Immunoassay

Slide 57

Slide 57 text

ImmunoassayOn-Chip

Slide 58

Slide 58 text

Immunoassay Detection System LED Microfluidc Chip Optical Filter Detector Insertion Port

Slide 59

Slide 59 text

Immunoassay Detection System LED Microfluidc Chip Optical Filter Detector Insertion Port

Slide 60

Slide 60 text

Immunoassay Rotation Speed

Slide 61

Slide 61 text

Immunoassay Calibration Curves 1.0 0.8 0.6 0.4 0.2 0.0 Fluorescence (mV) 2.5x10 4 2.0 1.5 1.0 0.5 0.0 E. Coli O157:H7 (CFU/mL) '0 mm/s' '1,7 mm/s'

Slide 62

Slide 62 text

Immunoassay Calibration Curves 1.0 0.8 0.6 0.4 0.2 0.0 Fluorescence (mV) 2.5x10 4 2.0 1.5 1.0 0.5 0.0 E. Coli O157:H7 (CFU/mL) '0 mm/s' '1,7 mm/s'

Slide 63

Slide 63 text

Immunoassay Sensitivity Detection Limit 2,7-fold Enhancement 603 CFU/mL

Slide 64

Slide 64 text

Immunoassay Sensitivity Detection Limit 2,7-fold Enhancement 603 CFU/mL

Slide 65

Slide 65 text

To sum up...

Slide 66

Slide 66 text

Analytical Potential

Slide 67

Slide 67 text

Analytical Potential Magnetic Beads Lab on a Chip

Slide 68

Slide 68 text

Analytical Potential Magnetic Beads Lab on a Chip Magnetic Actuator

Slide 69

Slide 69 text

Analytical Potential Magnetic Beads Lab on a Chip Magnetic Actuator Detection E.Coli O157:H7 2,7-fold Sensitivity Enhancement Detection Limit 603 CFU/mL

Slide 70

Slide 70 text

No content

Slide 71

Slide 71 text

Thank You very much for your attention!