– one Green) are located in front of the light source of the illuminator. By the different light breaking coefficients of steam and water you have a clear indication: Water (Green) and Steam (Red).
Material Carbon Steel (FS/H) Mica shields Single Size I ( Vis= 93 mm) Multiple Sections available Suitable for shut-off Fittings: - for KTA & KTA 225 DVK-2 - for KT 75: DVK-2 or DA - for KT 25: DA or D Back illuminator Transparent Bi-Colour Level Gauges Technical data
of the Bi-colour Models A COMPLETE FAMILY Designed in Klinger KTA-225 up to 225 bar Steam KTA- up to 180 bar Steam KT-75 up to 75 bar Steam KT-25 up to 25 bar Steam
is always identifiable due to the different colours, even when located into the blind area Camera can be used to monitor the level indication in the control room Bi-colour Level Gauges are suitable for very high operating pressures and temperatures
Graphite Sealing with Klinger soft packing Sleeve. Vessel Connection Flanged or NPT Connection to Gauge: 5/8” MALE (left thread) - ROTATABLE Gauge Cock DA
Steam, under real service condition HIGH VALUE LOW COST - Competitive Range and Price, according to the service conditions - Large Design Safety factor for a high product reliability - European Materials of certified first quality - Klinger Know How and experience - Standard components used - Standard spare parts, always available by stock - Long life in service, limited and easy maintenance