AMERICA National Labs + Research Teams • Reduce home energy use by 50% • Durable, Healthy & Comfortable Homes • Best Practice Research & Technologies PROGRAM GOALS: :
CONDITIONS ASHRAE STANDARD 160: 2 x 90% RH for concrete 2 x 80% RH for all other materials NEW CONSTRUCTION [NC] with wet construction materials EXISTING & NC* *with dry construction materials 90% RH for concrete 80% RH for all other materials T = 68 oF
thick / 3 wythe 1 Wythe Face Brick A 2 Wythes Fill Brick OUT IN + •High Density •Low Permeability •Med. Density •High Permeability B 3 Wythes Fill Brick •Med. Density •High Permeability Simulation Cases
RUN TIME INITIAL CONDITIONS [ASHRAE 160] : 03 Years [typical] : 10 Years [to assess brick drying time] : 80% RH : 68 oF T T = Temperature RH = Relative Humidity For Existing Buildings
GROWTH POTENTIAL [ASHRAE] T and RH at Potential Condensation Surfaces CONDENSATION POTENTIAL Interior Air T and RH MOISTURE CONTENT + DRYING TIME Moisture Content in Brick [ Vol-%] FAILURE CRITERIA WUFI OUTPUT FILES FROST DAMAGE T at Outer Wythe
Vapor Barrier: How To Use WUFI and THERM for Hygrothermal Modeling Upcoming Seminar: bit.ly/RKeiDw SimBuild 2012 Paper: bit.ly/Phf1X0 Our Technical Report: Can’t get enough?